Towards Automatic Localization and Anatomical Labeling of Intracranial Depth Electrodes in Brain Images

Published in Engineering in Medicine and Biology Conference, 2020

Recommended citation: Huynh C, Li, A Gonzalez-Martinez J, Sarma SV. Towards Automatic Localization and Anatomical Labeling of Intracranial Depth Electrodes in Brain Images. Conf Proc IEEE Eng Med Biol Soc. 2020. https://sarmalab.icm.jhu.edu/publications/

This conference paper was accepted at EMBC 2020. It outlines the algorithm implemented in Python for semi-automatically localizing and labeling SEEG depth electrodes in 3D images of brain volumes. Fully automating this task is left to future work.

The pipeline is available for viewing under Github.

See the paper here